A landlord compliance checklist is a list of every legal check, certificate and deadline a rented home must meet, in the order you meet them. In England, the core items are Right to Rent checks, an EPC, a gas safety record, an electrical report (EICR), working smoke and carbon monoxide alarms, any licence the council needs, and a protected deposit. Most come with a fixed renewal date, which is why missed deadlines, not missing knowledge, cause most problems.
This guide walks through the whole tenancy, from before you let to after the tenant leaves. At the end there's a single table you can copy, with how often each thing is needed and the official source.
This applies to England. Wales, Scotland and Northern Ireland have different rules. There's a short section on the differences near the end.
Contents
- Before the tenancy
- At the start
- During the tenancy
- At the end
- The full landlord compliance checklist table
- England vs Wales vs Scotland
- Frequently asked questions
Before the tenancy
Most of the work happens before the tenant gets the keys. If any of these is missing on move-in day, fix it before you hand over keys, not after.
Right to Rent
A Right to Rent check confirms that a tenant is allowed to rent a home in the UK. Gov.uk says you must check every tenant aged 18 or over before the tenancy starts, even if they aren't named on the agreement. If someone only has permission to stay for a limited time, the check must be done in the 28 days before the tenancy starts.
A new Home Office code of practice came into force on 1 October 2026. Key points:
- Fines are per occupier: £10,000 for a first breach and £20,000 for a repeat breach within three years (£5,000 and £10,000 for lodgers).
- If a tenant's right to rent is time-limited, you must do a follow-up check before your "statutory excuse" runs out. That's your legal protection from a fine, and it lasts until the latest of 12 months from the check, the end of their permission to stay, or the expiry of their document.
- If an agent agrees in writing to do the checks, the agent rather than the landlord is liable for any fine.
- For online and identity-provider checks, keep a copy for the whole tenancy and one year after.
EPC
An Energy Performance Certificate (EPC) rates how energy-efficient a home is, from A (best) to G. Gov.uk says you need one before you market a home to let, you must show it to the tenant, and it's valid for 10 years.
There's also a minimum rating. Under the minimum energy efficiency standard, since 1 April 2020 you can't let or keep letting most homes rated F or G unless you've registered a valid exemption. The spending cap for improvements to reach E is £3,500 including VAT. Fines go up to £5,000 per property.
What's coming. On 21 January 2026, the government published its response to its consultation. It plans a new minimum equal to EPC C by 1 October 2030, with the cost cap raised to £10,000. The regulations haven't been made yet. The government says it aims for them to come into force in 2027. So treat 2030 as the plan, not yet the law, and check gov.uk for updates.
Gas safety record
If the home has gas appliances or flues you provide, a Gas Safe registered engineer must check them at least every 12 months, and before a new tenancy the last check must be less than 12 months old (regulation 36). Since 6 April 2018, a check done up to two months early still counts as done on the deadline (regulation 36A), so you don't lose any time.
New tenants must get a copy before they move in. Current tenants get one within 28 days of each check. Keep each record until two more checks have been done (HSE).
EICR (electrical safety)
An EICR, or Electrical Installation Condition Report, is an electrician's report on the fixed wiring. Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, in force since 1 June 2020, the wiring must be inspected and tested at least every five years, or sooner if the report says so.
You must give a copy to new tenants before they move in, to current tenants within 28 days of the inspection, and to the council within 7 days if it asks in writing. Any dangerous items (coded C1, C2 or FI) must be dealt with within 28 days or sooner if the report says. The government guidance says councils can fine up to £40,000.
Smoke and carbon monoxide alarms
Under the rules as amended from 1 October 2022, the government booklet says you must:
- fit at least one smoke alarm on every storey with a room used as living space;
- fit a carbon monoxide alarm in any room used as living space that has a fixed combustion appliance (like a boiler or wood burner), except gas cookers;
- check every alarm works on the day a new tenancy starts;
- repair or replace any faulty alarm once you're told about it.
Councils can fine up to £5,000 if you don't follow a notice telling you to fix it.
Licensing (HMO and selective)
A house in multiple occupation (HMO) is a home shared by people from more than one household. Gov.uk says a licence is mandatory for a large HMO rented to 5 or more people from more than 1 household who share a kitchen, bathroom or toilet. A licence lasts up to five years.
Many councils also run additional licensing (for smaller HMOs) or selective licensing (for most rented homes in an area). These vary street by street, so check with the council for every new instruction. Letting an unlicensed HMO can lead to an unlimited fine.
Written terms and the Information Sheet
The Renters' Rights Act 2025 changed what tenants must be given in writing.
- For new tenancies from 1 May 2026, the required written terms are set by S.I. 2026/324, the Assured Tenancies (Private Rented Sector) (Written Statement of Terms etc and Information Sheet) (England) Regulations 2026. Use a tenancy agreement template that has been updated for these rules.
- For tenancies that existed before 1 May 2026 with written terms, gov.uk says most landlords and agents had to give each named tenant the official Renters' Rights Act Information Sheet 2026 by 31 May 2026. It must be the exact gov.uk PDF, as a printout or attachment, not a link. The fine can be up to £7,000.
Older checklists also list the "How to Rent" guide. The government withdrew it on 1 May 2026 and now keeps it only for tenancies where a Section 21 notice was served before that date (gov.uk: How to Rent). So you don't need to hand it to new tenants any more.
At the start
Deposit protection within 30 days
If you take a deposit, you must protect it in a government-approved scheme within 30 days of receiving it (gov.uk). There are three schemes in England: the Deposit Protection Service, MyDeposits and the Tenancy Deposit Scheme.
The deposit can't be more than five weeks' rent (or six weeks if the yearly rent is £50,000 or more) under the Tenant Fees Act 2019.
Prescribed information
Within the same 30 days, you must give the tenant the "prescribed information", a set list of facts about the deposit and the scheme. Get it wrong and, since 1 May 2026, a court can't usually make a possession order on the tenancy until it's fixed or the deposit is returned (Housing Act 2004, s.215). Our guide to tenancy deposit protection covers the detail.
Inventory
An inventory isn't a legal requirement, but it's your main evidence in any deposit dispute. Record each room's condition with dated photos and ask the tenant to agree it. A missing inventory makes it very hard to claim for damage later.
Example: a move-in week
Say a tenant moves in on Monday 15 March 2027 and pays the deposit on 1 March.
| Date | Task |
|---|---|
| 1 March | Deposit received; 30-day clock starts |
| 2 March | Right to Rent checks done for both adults |
| 3 March | Deposit registered; prescribed information sent |
| 10 March | Gas record (checked in January) and EICR (2024) copies sent |
| 15 March | Alarms tested on move-in day; inventory agreed |
| 30 March | Last day for deposit protection and prescribed information |
During the tenancy
Annual gas check
Book it every year, ideally inside the two-month early window. Give the tenant the new record within 28 days. If the tenant won't let you in, keep a dated record of every attempt.
Repairs and inspections
You're responsible for keeping the home safe and in good repair. Gov.uk lists duties like keeping the electrics and supplied appliances safe and making sure escape routes stay clear.
Regular inspections, every few months for most homes, help you spot problems early. Give the tenant proper notice before you visit.
Rent increases
Since 1 May 2026, rent on a private assured tenancy can only go up once a year using the Section 13 process. Our guide to the section 13 rent increase walks through it step by step. For the wider changes, see our renters rights act guide.
Renewals that come up mid-tenancy
These are the dates that sneak up during a long tenancy:
- the EICR's five-year date (or sooner);
- the EPC's 10-year expiry (it only needs renewing when you next market the home, but check before you do);
- the HMO or selective licence renewal;
- follow-up Right to Rent checks for time-limited permission.
At the end
Deposit return
Return the deposit within 10 days of you and the tenant agreeing how much they'll get back (gov.uk). If you can't agree, the deposit stays protected while the scheme's dispute service decides.
Check-out
Do a check-out report in the same format as the check-in inventory, room by room, with dated photos. Comparing the two is how you show what changed. Keep both reports, the scheme records and any repair quotes.
The full landlord compliance checklist table
Copy this into your own system. Each row is for one property in England.
| Requirement | When / how often | Who gets a copy | Official source |
|---|---|---|---|
| Right to Rent check | Before the tenancy; follow-up if time-limited | Keep for tenancy + 1 year | Home Office code, 1 Oct 2026 |
| EPC (E or better) | Before marketing; valid 10 years | Shown to the tenant | gov.uk EPC |
| Gas safety record | Every 12 months; less than 12 months old at move-in | Current tenants within 28 days; new tenants before move-in | Reg. 36, 1998 Regulations |
| EICR | At least every 5 years, or sooner if stated | Tenants within 28 days or before move-in; council within 7 days of request | 2020 Regulations, reg. 3 |
| Electrical repairs (C1, C2, FI) | Within 28 days or sooner | Written confirmation to tenants within 28 days of the work | 2020 Regulations, reg. 3 |
| Smoke alarm on each storey | Fitted; tested on day one of each new tenancy | n/a | Alarms booklet |
| CO alarm (rooms with fixed combustion appliances) | Fitted; tested on day one of each new tenancy | n/a | Alarms booklet |
| HMO / council licence | Up to 5 years; renew before expiry | Council | gov.uk HMO licence |
| Written terms (new tenancies) | Before or at the start, from 1 May 2026 | Tenant | S.I. 2026/324 |
| Information Sheet (pre-May 2026 tenancies) | By 31 May 2026 | Each named tenant | gov.uk Information Sheet |
| Deposit protected | Within 30 days of receipt | Scheme certificate to tenant | gov.uk deposits |
| Prescribed information | Within 30 days of receipt | Tenant (and anyone who paid) | gov.uk prescribed information |
| Deposit returned | Within 10 days of agreement | Tenant | gov.uk deposits |
| Client money protection (agents) | Ongoing membership | Certificate in office and online | gov.uk CMP |
What's next: the PRS Database
The government's roadmap, published 13 November 2025, says a new Private Rented Sector Database will start rolling out from late 2026. Signing up will be mandatory for landlords. As a minimum, it expects landlords to provide gas and electrical safety records and EPCs. The exact timing and fee will be confirmed nearer the launch, so watch gov.uk.
That's one more reason to keep every certificate as a dated, findable record and not a PDF in an inbox.
England vs Wales vs Scotland: where rules differ
This checklist is for England. The other UK nations have their own renting laws, and the differences go beyond small details.
- Wales: Renting is under its own law. Landlords must register and anyone managing property, including agents, must be licensed through Rent Smart Wales.
- Scotland: Scotland has its own tenancy system and a national register of landlords, run with local councils.
- Northern Ireland: NI Direct says all landlords letting under a private tenancy must register, with a certificate valid for three years.
Gas safety law covers Great Britain, so annual gas checks apply in Wales and Scotland too. But electrical, EPC, deposit and tenancy rules differ, so use each nation's official guidance for properties there.
How agents keep this under control
One property is a checklist. A hundred properties is a calendar with hundreds of dates. The agencies that stay on top of compliance usually do three things:
- Every certificate is a record with an expiry date, attached to the property, not a file in someone's email.
- Reminders go out well before each date, to the person responsible and to the landlord, who often pays for the work.
- Nothing goes to move-in until every item is green.
Fivura tracks 16 certificate types, including gas, electrical, EPC, fire safety, Legionella and licences, with UK rule sets built in. It shows what's missing for each property and sends reminders to your team and the landlord 30, 14, 7 and 1 day before a certificate expires, and again after. You can also share certificates with tenants and landlords in one click.
Related guides: Landlord Gas Safety Certificate, EICR Landlord Guide, EPC Rental Property Rules, Smoke Alarm Regulations Landlords Must Follow, Landlord Certificate Reminders.
Frequently asked questions
What certificates does a landlord need?
In England, the main three are a gas safety record (renewed every 12 months if there's gas), an Electrical Installation Condition Report (at least every five years) and an Energy Performance Certificate (valid for 10 years, and rated E or better to let). You may also need a property licence from the council, and you must keep proof of Right to Rent checks and deposit protection.
How often is an EICR needed?
At least every five years, under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. If the last report asks for an earlier check, you must follow that shorter date. You must give current tenants a copy within 28 days of the inspection, new tenants before they move in, and the council within seven days if it asks in writing.
What happens if a landlord isn't compliant?
It depends on the rule. Councils can fine up to £40,000 for electrical safety breaches and up to £30,000 for agents not in a client money scheme. Gas safety breaches are criminal offences HSE can prosecute. An unprotected deposit can cost up to three times the deposit and can block a possession order. Right to Rent fines run up to £20,000 per occupier.
Do the same rules apply in Wales and Scotland?
No. This checklist is for England. Wales has its own renting law and requires landlords and agents to register and get licences through Rent Smart Wales. Scotland has its own tenancy system and a national landlord register. Northern Ireland requires private landlords to register too. Some safety rules overlap, but always check the official guidance for the nation the property is in.
Track it all in one place
Track every certificate and expiry in one place: try Fivura's compliance tracking.
How we wrote this: on 4 November 2026 we checked every rule above against gov.uk, legislation.gov.uk, HSE, the Home Office Right to Rent code of practice (1 October 2026), Rent Smart Wales, the Scottish landlord register and NI Direct. The 2030 EPC target is a government plan; the regulations had not been made when we checked. The Fivura Editorial Team wrote this guide. No lawyer has reviewed it.
This guide is general information, not legal or tax advice. Check the official guidance linked above or speak to a qualified adviser.